Intel 2 Duo T9300 EC80576GG0606M Benutzerhandbuch
Produktcode
EC80576GG0606M
Electrical Specifications
26
Datasheet
3.4
Catastrophic Thermal Protection
The processor supports the THERMTRIP# signal for catastrophic thermal protection. An
external thermal sensor should also be used to protect the processor and the system
against excessive temperatures. Even with the activation of THERMTRIP#, which halts
all processor internal clocks and activity, leakage current can be high enough that the
processor cannot be protected in all conditions without the removal of power to the
processor. If the external thermal sensor detects a catastrophic processor temperature
of 125°C (maximum), or if the THERMTRIP# signal is asserted, the V
CC
supply to the
processor must be turned off within 500 ms to prevent permanent silicon damage due
to thermal runaway of the processor. THERMTRIP# functionality is not ensured if the
PWRGOOD signal is not asserted, and during package C6.
1
1
0
0
0
1
0
0.2750
1
1
0
0
0
1
1
0.2625
1
1
0
0
1
0
0
0.2500
1
1
0
0
1
0
1
0.2375
1
1
0
0
1
1
0
0.2250
1
1
0
0
1
1
1
0.2125
1
1
0
1
0
0
0
0.2000
1
1
0
1
0
0
1
0.1875
1
1
0
1
0
1
0
0.1750
1
1
0
1
0
1
1
0.1625
1
1
0
1
1
0
0
0.1500
1
1
0
1
1
0
1
0.1375
1
1
0
1
1
1
0
0.1250
1
1
0
1
1
1
1
0.1125
1
1
1
0
0
0
0
0.1000
1
1
1
0
0
0
1
0.0875
1
1
1
0
0
1
0
0.0750
1
1
1
0
0
1
1
0.0625
1
1
1
0
1
0
0
0.0500
1
1
1
0
1
0
1
0.0375
1
1
1
0
1
1
0
0.0250
1
1
1
0
1
1
1
0.0125
1
1
1
1
0
0
0
0.0000
1
1
1
1
0
0
1
0.0000
1
1
1
1
0
1
0
0.0000
1
1
1
1
0
1
1
0.0000
1
1
1
1
1
0
0
0.0000
1
1
1
1
1
0
1
0.0000
1
1
1
1
1
1
0
0.0000
1
1
1
1
1
1
1
0.0000
Table 2.
Voltage Identification Definition (Sheet 4 of 4)
VID6
VID5
VID4
VID3
VID2
VID1
VID0
V
CC
(V)