Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 4.2(3)
OL-19964-04
  Caveats
9    5.2(1)          1.0     22:01:00:0d:ec:25:e9:80 to 22:12:00:0d:ec:25:e9:80 
Mod  MAC-Address(es)                         Serial-Num
---  --------------------------------------  ----------
9    00-1a-e2-03-4c-5c to 00-1a-e2-03-4c-64  JAE1131SCBW
switch# sh sprom module 9 1 |egrep "Part|Serial"
 Serial Number   : JAE1131SCBW
 Part Number     : 73-10688-06     <-- Not 73-14372-01 so h/w ver 1.0 is OK
 Part Revision   : A0
Workaround: Upgrade to software release that has the fix for this issue.
After performing a software upgrade to a Cisco NX-OS release that contains a fix for this issue, 
it may be necessary to enter the shut command followed by the no shut command on the 
affected host ports to regain connectivity.
If you perform a nondisruptive upgrade or downgrade from a release that contains a fix to a 
release that does not contain the fix, you need to reload each module affected by this issue.
If you have a Cisco MDS 9222i swtich that is affected by this issue, and you perform a 
nondisruptive upgrade or downgrade from a release that contains a fix to a release that does not 
contain the fix, you need to reload the switch.
CSCsq20408
Symptom: The show startup command displays aspects of the running configuration when 
SANTap is configured and/or SANTap objects are created. When a user creates objects such as a 
CVT or DVT, the configuration is showing in the running-configuration and in the 
startup-configuration without copying the configuration into the startup-configuration.
Workaround: Issue a copy running-config startup-config command whenever you create objects 
such as a CVT or DVT so that the running-configuration and startup-configuration are 
synchronized.
CSCsy37951
Symptom: The Trunking F PortChannels feature is not available in NX-OS Release 4.1(1x); 
however, a downgrade from Release 4.1(3a) or later to Release 4.1(1x) is nondisruptive, even when 
the Trunking F PortChannels feature is enabled (using the feature fport-channel-trunk command) 
while running Release 4.1(3a) or later.
Workaround: If a downgrade to Release 4.1(1x) is performed when the Trunking F PortChannels 
feature is enabled, the switch will be in an inconsistent state. You must reload the switch after a 
downgrade to Release 4.1(1x).
CSCtn68418 
Symptom: When you try to save a configuration, you might see the following message: 
switch# copy run start
[########################################] 100%
Configuration update aborted: request was aborted
 %DAEMON-3-SYSTEM_MSG: ntp:can't open /mnt/pss/ntp.drift.TEMP: No space left on 
device 
- ntpd[xxxx]
%PLATFORM-2-MEMORY_ALERT: Memory Status Alert : MINOR
%PLATFORM-2-MEMORY_ALERT: Memory Status Alert : MINOR ALERT RECOVERED
`show system internal flash` output will display /isan as 100% full.
Mount-on                  1K-blocks      Used   Available   Use%  Filesystem