PLIM 0/2/CPU0 : 8-10GbE
  ROMMON: Version 1.32(20050525:193559)  [CRS-1 ROMMON]
NODE 0/6/SP : MSC(SP)
  ROMMON: Version 1.32(20050525:193402)  [CRS-1 ROMMON]
PLIM 0/6/CPU0 : 16OC48-POS/DPT
  ROMMON: Version 1.32(20050525:193559)  [CRS-1 ROMMON]
NODE 0/RP0/CPU0 : RP
  ROMMON: Version 1.32(20050525:193559)  [CRS-1 ROMMON]
NODE 0/RP1/CPU0 : RP
  ROMMON: Version 1.32(20050525:193559)  [CRS-1 ROMMON]]
NODE 0/SM0/SP : FC/S
  ROMMON: Version 1.32(20050525:193402)  [CRS-1 ROMMON]
NODE 0/SM1/SP : FC/S
  ROMMON: Version 1.32(20050525:193402)  [CRS-1 ROMMON]
NODE 0/SM2/SP : FC/S
  ROMMON: Version 1.32(20050525:193402)  [CRS-1 ROMMON]
NODE 0/SM3/SP : FC/S
  ROMMON: Version 1.32(20050525:193402)  [CRS-1 ROMMON]
Notes
ROMMON 1.32 is not backward compatible with a Cisco IOS XR Software Release earlier than 
Release 3.2.0, except for Release 3.0.1. However, with Cisco IOS XR Software Release 3.0.1, a 
SMU is required to be installed before the ROMMON upgrade can take place. 
The required SMU for Cisco IOS XR Software Release 3.0.1 to be compatible with ROMMON 1.32 
is comp-hfr-001.CSCee55511; this must be installed before the ROMMON upgrade.
Use the show platform command to retrieve the location IDs. 
Note
The help “?” does not always displays all nodes:
RP/0/RP1/CPU0:CRS-B(admin)# show platform
Node            Type            PLIM            State           Config State
-----------------------------------------------------------------------------
0/0/SP          MSC(SP)         N/A             IOS-XR RUN      PWR,NSHUT,MON
0/0/CPU0        MSC             4OC192-POS/DPT  IOS-XR RUN      PWR,NSHUT,MON
0/2/SP          MSC(SP)         N/A             IOS-XR RUN      PWR,NSHUT,MON
0/2/CPU0        MSC             8-10GbE         IOS-XR RUN      PWR,NSHUT,MON
0/6/SP          MSC(SP)         N/A             IOS-XR RUN      PWR,NSHUT,MON
0/6/CPU0        MSC             16OC48-POS/DPT  IOS-XR RUN      PWR,NSHUT,MON
0/RP0/CPU0      RP(Active)      N/A             IOS-XR RUN      PWR,NSHUT,MON
0/RP1/CPU0      RP(Standby)     N/A             IOS-XR RUN      PWR,NSHUT,MON
0/SM0/SP        FC/S(SP)        N/A             IOS-XR RUN      PWR,NSHUT,MON
0/SM1/SP        FC/S(SP)        N/A             IOS-XR RUN      PWR,NSHUT,MON
0/SM2/SP        FC/S(SP)        N/A             IOS-XR RUN      PWR,NSHUT,MON
0/SM3/SP        FC/S(SP)        N/A             IOS-XR RUN      PWR,NSHUT,MON
After the ROMMON upgrade is complete, when adding new cards to the router, check the 
ROMMON version and upgrade it if necessary.  In those cases, instead use the location node-id 
command for the card just inserted.