Cisco Cisco Firepower 4110 Security Appliance Installationsanleitung

Seite von 10
4
Cisco Firepower Threat Defense for Firepower 4100 Quick Start Guide
The console port is physically connected to a computer terminal or console server.
The 1 Gbps Ethernet management port is connected to an external hub, switch, or router.
For more information, see the Cisco Firepower Chassis Manager Configuration Guide.
Procedure
1.
Connect to the Firepower 4100 CLI, either from the console port or using SSH, for example. 
2.
Log in with the username 
admin
 and the password 
cisco123
3.
Complete the system configuration as prompted. 
For example:
Enter the setup mode; setup newly or restore from backup. (setup/restore) ? setup
You have chosen to setup a new Security Appliance. Continue? (y/n): y
Enforce strong password? (y/n): n
Enter the password for “admin”: <new password>
Confirm the password for “admin”: <repeat password>
Enter the system name: FTD-SSP-4100
Physical Switch Mgmt0 IP address : 10.127.56.61
Physical Switch Mgmt0 IPv4 netmask : 255.255.255.0
IPv4 address of default gateway : 10.127.56.1
Configure the DNS Server IP address? (yes/no) [n]: n
Configure the default domain name? (yes/no) [n]: n
Following configurations will be applied:
Switch Fabic=A
System Name=FTD-SSP-4100
Enforced Strong Password=no
Physical Switch Mgmt0 IP Address=10.127.56.61
Physical Switch Mgmt0 IP Netmask=255.255.255.0
Default Gateway=10.127.56.1
Ipv6 value=0
Apply and save the configuration (select ‘n’ if you want to re-enter)? (yes/no): yes
Applying configuration. Please wait. 
4.
Launch the Firepower Chassis Manager Web Interface to verify connectivity using the new log in credentials. 
a.
Using a supported browser, enter the following URL in the address bar:
https://<chassis_mgmt_ip_address>
where <chassis_mgmt_ip_address> is the IP address or host name of the Firepower 4100 that you entered 
during initial configuration.
b.
Enter your username and password.
c.
Click Login.
You are logged in and the Firepower Chassis Manager Web Interface opens to show the Overview page. 
Configure NTP
Your Firepower Threat Defense deployment on the Firepower 4100 requires that you configure NTP on the 
Firepower Chassis Manager. The NTP server must be set on the Firepower Chassis Manager for Smart Licensing 
to work properly and to ensure proper timestamps on device registrations.