Release Notes for Cisco Intrusion Prevention System 7.0(2)E4
OL-21671-01
  The Sensor and Jumbo Packet Frame Size
The Sensor and Jumbo Packet Frame Size
For IPS standalone appliances with 1 G and 10 G fixed or add-on interfaces, the maximum jumbo frame 
size is 9216 bytes. 
Note
A jumbo frame is an Ethernet packet that is larger than the standard maximum of 1518 bytes (including 
Layer 2 header and FCS).
MySDN Decommissioned
Because MySDN has been decommissioned, the URL in older versions of the IDM and the IME is no 
longer functional. If you are using IPS 6.0 or later, we recommend that you upgrade your version of the 
IDM and the IME.
You can upgrade to the following versions to get the functioning MySDN URL:
IDM 7.0.3
IME 7.0.3
IPS 7.0(4)E4, which contains IDM 7.0.4
If you are using version IPS 5.x, you must look up signature information manually at this URL:
For More Information
For detailed information on MySDN, for the IDM refer to 
 and for the IME refer to 
Cisco IPS Device Manager
A new version of the IDM is bundled with the E4 engine update, IDM 7.0.3. We have modified the IDM 
to correctly display and edit the additional values allowed in the Retired parameter field of a signature. 
We have also modified the IDM and its associated ASDM Launcher application to increase the upper 
memory limit that Java VM uses. With this change you can display and tune more signatures in the IDM.
Note
We recommend that ASDM users upgrade to ASDM 6.3 or later. The Java VM upper memory limit of 
ASDM 6.3 has been increased. Older versions of ASDM may not have enough available memory for 
IDM7.0.3 to function properly.
Note
After upgrading to the E4 signature engine, disconnect and restart any open IDM sessions to make sure 
that your system downloads and uses the latest IDM application from the sensor.
For More Information
For more information about the new values allowed in the Retired parameter for a signature, see