Cisco Cisco IPS 4255 Sensor

Seite von 36
19
Release Notes for Cisco Intrusion Prevention System 5.1(8)E3
OL-20155-01
Upgrading to Cisco IPS 5.1(8)E3
You cannot uninstall the5.1(8)E3 service pack. You must reimage the sensor using a system image 
file.  All configuration settings are lost.
Auto Update does not recognize the IPS-4260 package file (IPS-4260-K9-5.1-8-E3.pkg).
If Auto Update is configured on the IPS-4260, it does not install the 4260 files because it does not 
recognize them. Use the CLI or IDM to install the5.1(8)E3 service pack.
Note
IPS version 5.1(x) does not recognize platform-specific major, minor, or service pack file 
names.
If you have 4.0 installed on your sensor, you must upgrade to 4.1, then upgrade to 5.0, then upgrade 
to 5.1(8)E3.
If you try to upgrade a 4.0 sensor to 5.0, you receive an error that Analysis Engine is not running 
rather than an error that the sensor cannot be upgraded from 4.0 to 5.0:
sensor# upgrade scp://user@10.1.1.1/upgrades/IPS-K9-maj-5.0-1-S148.rpm.pkg
Password: ********
Warning: Executing this command will apply a major version upgrade to the application 
partition. The system may be rebooted to complete the upgrade.
Continue with upgrade? : yes
Error: AnalysisEngine is not running. Please reset box and attempt upgrade again.
If you receive this error, you must upgrade from 4.0 to 4.1 and then to 5.0. Or you can use the 
recovery CD (if your sensor has a CD-ROM) or the system image file to reimage directly to 
version 5.1(8)E3. You can reimage a 4.0 sensor to 5.0 because the reimage process does not check 
to see what version was previously installed.
After you upgrade any IPS software on your sensor, you must restart the IDM to see the latest 
software features. 
In 4.x, custom signature IDs start at 20000. Any custom signatures that you have created in 4.x are 
converted to the 5.x custom signature range, which begins at 60000.
In 4.x, there is a parameter that lets you enable and disable signatures. In 5.x, there is a similar 
parameter, but there is also a parameter that lets you retire and unretire signatures. When you 
upgrade to 5.x, some signatures will be marked as enabled; however, they may also have been retired 
in 5.x and therefore the enabled setting is ignored. You must manually unretire the signature to 
ensure that it is enabled. 
In 5.1(8)E3, you will receive messages indicating the you need to install a license. The sensor 
functions properly without a license, but you will need a license to install signature updates. 
Upgrading from 4.1 to 5.x preserves the configuration of the sensor. The upgrade may stop if it 
comes across a value that it cannot translate. If this occurs, the resulting error message provides 
enough information to adjust the parameter to an acceptable value. After editing the configuration, 
try the upgrade again.
After you upgrade from 4.x to 5.0, you cannot downgrade. If you want to return to the previous 
version, you must reimage and then copy the backup configuration to the reimaged sensor. You 
cannot downgrade from 5.1(8)E3 to 5.0.
IDS MC cannot manage sensors that have been upgraded to 5.x until the IDS MC 2.1 release.
For More Information
For the procedure for changing the status of signatures, refer to 
.
For the procedure for obtaining and installing the license, see 
.