Cisco Cisco Firepower 9300 Security Appliance Merkblatt
2-175
Cisco Firepower 机箱管理器故障和错误消息 1.1(1)
第 2 章 Firepower 9300 故障
Type:
configuration
Callhome:
none
Auto Cleared:
true
Is Implemented:
true
Affected MO:
fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def
-[name]/if-[name]
Affected MO:
fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO:
fabric/lanmon/eth-flow-monitoring/flow-exporter-profile-[name]/if-[name]
Affected MO:
org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO:
org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO:
org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO:
org-[name]/ls-[name]/if-[name]
Affected MO:
org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO:
org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO:
org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO:
org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]
fltVnicEtherIfInvalidVlan
故障代码:F0934
消息
允许的 VLAN 列表中存在无效 VLAN (Invalid Vlan in the allowed vlan list)
说明
当服务配置文件或端口配置文件的 vNIC 包含无效 VLAN 时,通常会发生此故障。无效 VLAN 可
能为以下任意项:
能为以下任意项:
步骤 1
未与有效主 VLAN 关联的隔离 VLAN 或社区 VLAN。
步骤 2
vNIC 上未允许其任何关联辅助 VLAN 的主 VLAN。
步骤 3
共享类型或主 LAN 名称与 LAN 端/设备端中 VLAN 的共享类型或主 LAN 名称不匹配的 VLAN。
建议的操作
如果您执行下列操作之一,将会清除此故障:
步骤 1
如果无效 VLAN 为隔离 VLAN 或社区 VLAN,请确保其已映射至有效主 VLAN。
步骤 2
如果无效 VLAN 为主 VLAN,请允许其所有辅助 VLAN 或将其从 vNIC 或端口配置文件中删除。
步骤 3
如果无效 VLAN 为未将共享属性与 LAN 端/设备端中同一 VLAN id 的 VLAN 匹配的 VLAN,则
将此 VLAN 的属性改为与其余 VLAN 相同。
将此 VLAN 的属性改为与其余 VLAN 相同。
故障详细信息
Severity:
major
Cause:
invalid-vlan-in-the-allowed-vlan-list
mibFaultCode:
934
mibFaultName:
fltVnicEtherIfInvalidVlan
moClass:
vnic:EtherIf
Type:
configuration
Callhome:
none
Auto Cleared:
true
Is Implemented: