Cisco Cisco Firepower 9300 Security Appliance Merkblatt

Seite von 1532
2-186
Cisco Firepower 机箱管理器故障和错误消息 1.1(1)
 
  2      Firepower 9300 故障
说明 
注意:当驱动器重构操作失败时会发生此故障。这会导致性能降低。 
建议的操作 
如果发生此故障,请执行以下操作: 
步骤 1
重试重构操作。 
步骤 2
删除并重新创建虚拟驱动器。 
故障详细信息 
Severity:
 major 
Cause:
 equipment-degraded 
mibFaultCode:
 1009 
mibFaultName:
 fltStorageVirtualDriveReconstructionFailed 
moClass:
 storage:VirtualDrive 
Type:
 equipment 
Callhome:
 none 
Auto Cleared:
 true 
Is Implemented:
 false 
Affected MO:
 sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id] 
Affected MO:
 sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
fltStorageVirtualDriveConsistencyCheckFailed 
故障代码:F1010 
消息 
服务器 [机箱 Id]/[插槽 Id] 上虚拟驱动器 [id] 可操作性:[可操作性]。原因:[操作限定符原因] 服
务器 [id] 上虚拟驱动器 [id] 可操作性:[可操作性]。原因:[操作限定符原因] (Virtual drive [id] on 
server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on 
server [id] operability: [operability]. Reason: [operQualifierReason]) 
说明 
注意:当驱动器一致性检查操作失败时会发生此故障。这会导致性能降低。 
建议的操作 
如果发生此故障,请执行以下操作: 
步骤 1
重试一致性检查操作。 
步骤 2
删除并重新创建虚拟驱动器。 
故障详细信息 
Severity:
 major 
Cause:
 equipment-degraded 
mibFaultCode:
 1010 
mibFaultName:
 fltStorageVirtualDriveConsistencyCheckFailed 
moClass:
 storage:VirtualDrive 
Type:
 equipment