Cisco IW3702 Access Point Getting Started Guide
 
Overview
Note:
 If the vent is removed or damaged, the access point is subject to moisture damage.
Reset Button
You use the reset button to reset the access point or reload the software. The reset button is under the protective vent 
port. To access the reset button:
1.
Use a 5/8" socket to remove the protective vent.
2.
Press the reset button.
Press the reset button for 3 seconds to reset the access point to its factory settings.
Press the reset button for 20 seconds to reload the access point software.
3.
Replace the protective vent using 5/8" socket.
4.
Torque the protective vent to 5-7 inch-lbs. 
Console Port
You can connect the access point to a PC or laptop through the RJ45 CON port. The RJ45 CON port uses the Cisco 
console port RJ45-to-DB9 cable (Cisco PN 72-3383-01).
A cable port seal covers the CON port. This liquid-tight plug protects the access point from environmental elements. 
Ensure that the plug is installed during normal operation or when unit is unattended. You can remove and install the port 
plug with a 1/2" (13 mm) socket. Torque it to 6-7 ft-lbs
For more information, see 
Ground Stud
The ground stud is the access point ground. You use screws to attach the wired grounding lug to the ground stud 
(
). Connect the other end of the ground wire to an earth ground such as a grounding rod or 
appropriate ground point on a grounded pole.
Top Panel Components
This section describes the top panel components shown in 
.
Antenna Port
The antenna connector is a type N female coaxial connector.
Hard Points
The hard points are alternate mounting or attachment points for additional equipment such as directional antennas or 
covers.
Note:
 Do not attach third-party radios using these hard points.