Cisco Cisco Email Security Appliance C370 Technische Referenzen

Seite von 566
 
Chapter 
452
Cisco IronPort AsyncOS 7.5 CLI Reference Guide
OL-23407-01
- THROTTLING - Limit unique hosts tracked for rejected connection 
reporting.
- TLD - Add customer specific domains for reporting rollup.
- STORAGE - How long centralized reporting data will be stored on the 
C-series before being overwritten.
- LEGACY - Configure legacy mailflow report.
[]> storage
While in centralized mode the C-series will store reporting data for 
the M-series to collect.  If the M-series does not collect that data 
then eventually the C-series will begin to overwrite the oldest data 
with new data.
A maximum of 24 hours of reporting data will be stored.
How many hours of reporting data should be stored before data loss?
[24]> 48
SenderBase timeout used by the web interface: 5 seconds
Sender Reputation Multiplier: 3
The current level of reporting data recording is: unlimited
No custom second level domains are defined.
Legacy mailflow report: Disabled
Table 3-158
reportingconfig
 - Configure storage limit for centralized 
reporting data