Cisco Cisco Aironet 3800i Access Point Datenbogen
© 2017 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 6 of 12
Item
Specification
Interfaces
◦
2 Ethernet ports
◦
100/1000/2500/5000 Multigigabit Ethernet (RJ-45)
– IEEE 802.3bz
◦
CAT 5e cabling
◦
Higher-quality 10GBASE-T (CAT 6/6a) cabling
◦
100/1000BASE-T autosensing (RJ-45 - AUX port)
◦
Management console port (RJ-45)
Indicators
● Status LED indicates boot loader status, association status, operating status, boot loader warnings, boot loader
errors
Dimensions
(W x L x H)
(W x L x H)
● Access point (without mounting brackets): 3802I: 8.66 x 8.68 x 2.46 in. (22 x 22 x 6.25 cm), 3802E: 8.66 x 8.68 x
2.62 in. (22 x 22 x 6.7 cm), 3802P: 8.66 x 8.68 x 2.62 in. (22 x 22 x 6.7 cm)
Weight
● 4.6 lb (2.09 kg)
Input power
requirements
requirements
● 802.3at PoE+, Cisco Universal Power over Ethernet (Cisco UPOE
®
)
● 802.3at power injector (AIR-PWRINJ6=)
● 50W power supply (AIR-PWR-50=)
● 50W power supply (AIR-PWR-50=)
Power draw
● 30W at the PSE with all features enabled except for the USB 2.0 port
● 34W at the PSE with the USB 2.0 port enabled
● 34W at the PSE with the USB 2.0 port enabled
Environmental
Cisco Aironet 3800i
● Nonoperating (storage) temperature: -22° to 158°F (-30° to 70°C)
● Nonoperating (storage) altitude test: 25˚C, 15,000 ft.
● Operating temperature: 32° to 104°F (0° to 40°C)
● Operating humidity: 10% to 90% percent (noncondensing)
● Operating altitude test: 40˚C, 9843 ft.
● Nonoperating (storage) altitude test: 25˚C, 15,000 ft.
● Operating temperature: 32° to 104°F (0° to 40°C)
● Operating humidity: 10% to 90% percent (noncondensing)
● Operating altitude test: 40˚C, 9843 ft.
Cisco Aironet 3800e
● Nonoperating (storage) temperature: -22° to 158°F (-30° to 70°C)
● Nonoperating (storage) altitude test: 25˚C, 15,000 ft.
● Operating temperature: -4° to 122°F (-20° to 50°C)
● Operating humidity: 10% to 90% (noncondensing)
● Operating altitude test: 40˚C, 9843 ft.
● Nonoperating (storage) altitude test: 25˚C, 15,000 ft.
● Operating temperature: -4° to 122°F (-20° to 50°C)
● Operating humidity: 10% to 90% (noncondensing)
● Operating altitude test: 40˚C, 9843 ft.
Cisco Aironet 3800p
● Nonoperating (storage) temperature: -22° to 158°F (-30° to 70°C)
● Nonoperating (storage) altitude test: 25˚C, 15,000 ft.
● Operating temperature: -4° to 122°F (-20° to 50°C)
● Operating humidity: 10% to 90% (noncondensing)
● Nonoperating (storage) altitude test: 25˚C, 15,000 ft.
● Operating temperature: -4° to 122°F (-20° to 50°C)
● Operating humidity: 10% to 90% (noncondensing)
Operating
altitude test: 40˚C, 9843 ft.
System memory
● 1024 MB DRAM
● 256 MB flash
● 256 MB flash
Available transmit
power settings
power settings
2.4 GHz
● 23 dBm (200 mW)
● 20 dBm (100 mW)
● 17 dBm (50 mW)
● 14 dBm (25 mW)
● 11 dBm (12.5 mW)
● 8 dBm (6.25 mW)
● 5 dBm (3.13 mW)
● 2 dBm (1.56 mW)
● 20 dBm (100 mW)
● 17 dBm (50 mW)
● 14 dBm (25 mW)
● 11 dBm (12.5 mW)
● 8 dBm (6.25 mW)
● 5 dBm (3.13 mW)
● 2 dBm (1.56 mW)
5 GHz
● 23 dBm (200 mW)
● 20 dBm (100 mW)
● 17 dBm (50 mW)
● 14 dBm (25 mW)
● 11 dBm (12.5 mW)
● 8 dBm (6.25 mW)
● 5 dBm (3.13 mW)
● 2 dBm (1.56 mW)
● 20 dBm (100 mW)
● 17 dBm (50 mW)
● 14 dBm (25 mW)
● 11 dBm (12.5 mW)
● 8 dBm (6.25 mW)
● 5 dBm (3.13 mW)
● 2 dBm (1.56 mW)