Release Notes for 200, 300, 500, and ESW2 Series Switches Firmware Version 1.4.0
Release Notes
The following caveats are acknowledged in release 1.3.7.18:
Problem:
During SF500-24MP/48MP reset, the port GS4/S4 link is up for 5 
seconds. (CSCum85751)
Solution:
None.
The following caveats are carried forward from release 
1.3.5.58:
Problem:
Sometimes on the SG500XG-8F8T, the 10G copper port goes up and 
down continuously if it is configured to a speed of 1G, and hence the Lion stack 
performance have Losts of around 3% of frame loss. (CQ147378, CSCuj46317)
Solution:
Configure Nikola switch ports in 1G speed to Auto-negotiation 
preferred master.
Problem:
When setting a new key chain for RIP using the WEB GUI, if it does not 
include an accept-lifetime, it does not take effect, and only Key 1 takes effect with 
accept-lifetime. (CQ148403, CSCuh54765)
Solution:
Use the CLI for entering the key chain, or enter both accept-lifetime and 
send-lifetime. Only use Key 1 with accept-lifetime.
Problem:
WRR will lose efficacy after it is configured to egress shaping rate. 
(CQ146677, CSCuf82588)
Solution:
Configure the WRR again.
Problem:
When user tries to Telnet some other devices from switch, it takes a 
long time to logout. The user either needs to double click enter button or wait a long 
time to logout from the device and return to the switch. (CQ146113, CSCuj46177)
Solution:
The only option is to either double click enter key or wait for a long time 
to logout.
Problem:
On SG500XG-8F8T or SG500X, changing the stack mode from native 
to advanced-hybrid-xg causes the start-up configuration to be lost. (CQ148932, 
CSCui08988)
Solution:
Backup startup-config file before changing the stack mode.