Cisco Cisco Packet Data Gateway (PDG) Installationsanleitung

Seite von 195
  Technical Specifications 
Power Requirements  ▀   
 
ASR 5500 Installation Guide  ▄  
 
   
35 
 
 
Important:
  The DC power BR input terminal of the ASR 5500 is not connected to the equipment frame (chassis) 
and is configured as DC-I in compliance with GR-1089-CORE (sec.9.8.3). 
Example Power Calculations 
DPC/UPDC Full Chassis 
This calculation assumes that a fully redundant ASR 5500 chassis will be equipped with DPC/UDPCs. 
(8) DPC/UDPCs [8x630w] = 5040 watts 
(2) MIO/UMIOs [2x650w] = 1300 watts 
(4) FSCs [4x150w] = 600 watts 
(2) SSCs [2x10w] = 20 watts 
Fan Units [front and rear] = 2000 watts 
Total = approximately 9 kW 
DPC2/UDPC2 Full Chassis 
This calculation assumes that a fully redundant ASR 5500 chassis will be equipped with DPC2/UDPC2s. 
(8) DPC2/UDPC2s [8x760w] = 6080 watts 
(2) MIO/UMIOs [2x650w] = 1300 watts 
(4) FSCs [4x150w] = 600 watts 
(2) SSCs [2x10w] = 20 watts 
Fan Units [front and rear] = 2000 watts 
Total = approximately 10 kW