  Power Cabling 
Internal Power Planes  ▀   
 
ASR 5500 Installation Guide  ▄  
 
   
97 
Internal Power Planes 
Four inputs are labeled A1 through A4 and the other inputs are labeled B1 through B4. A1 is redundant for B1 and so 
on. The inputs correspond to the four power planes that supply power to various chassis components as shown in the 
table and figure below. 
The SSC monitors all eight feeds for outages. 
Important:
  All four power inputs on a PFU must be connected to live power feeds to assure that all card slots in 
the ASR 5500 chassis are energized. 
Chassis Power Card Slot Allocations 
Table 15.  Chassis Power Planes 
Card Type
 
Slot
 
Plane 1
 
Plane 2
 
Plane 3
 
Plane 4
 
Rear Cards
 
DPC or UDPC, DPC2
 
1
 
 
 
 
Yes
 
DPC or UDPC, DPC2 or UDPC2
 
2
 
 
 
 
Yes
 
DPC or UDPC, DPC2 or UDPC2
 
3
 
 
 
 
Yes
 
DPC or UDPC, DPC2 or UDPC2
 
4
 
 
Yes
 
 
 
MIO or UMIO
 
5
 
 
Yes
 
 
 
MIO or UMIO
 
6
 
 
 
Yes
 
 
DPC or UDPC, DPC2 or UDPC2
 
7
 
 
 
Yes
 
 
DPC or UDPC, DPC2 or UDPC2
 
8
 
Yes
 
 
 
 
DPC or UDPC, DPC2 or UDPC2
 
9
 
Yes
 
 
 
 
DPC or UDPC, DPC2 or UDPC2
 
10
 
Yes
 
 
 
 
Front Cards
 
SSC
 
11
 
 
Yes
 
 
 
SSC
 
12
 
 
Yes
 
 
 
FSC
 
13
 
Yes
 
 
 
 
FSC
 
14
 
 
 
Yes
 
 
FSC
 
15
 
 
 
Yes
 
 
FSC
 
16
 
 
Yes
 
 
 
FSC
 
17
 
 
Yes