Cisco Cisco Packet Data Gateway (PDG) Fehlerbehebungsanleitung

Seite von 5302
Global Configuration Mode Commands   
▀  threshold poll total-mme-sessions 
 
▄  Cisco ASR 5000 Series Command Line Interface Reference 
OL-22948-01   
threshold poll total-mme-sessions 
This command configures the polling interval over which to count or measure the thresholding value for MME sessions 
on the system. 
Product
 
MME 
Privilege
 
Security Administrator, Administrator 
Syntax
 
Restores the threshold poll interval value to its default value of 300 seconds. 
Default: 900 seconds 
Specifies the amount of time that comprises the polling interval over which to count the total number of 
MME sessions on the system. 
 is measured in seconds and can be configured to any integer value from 30 to 60000. 
Usage
 
This command dictates the time period over which to monitor the specified value for threshold crossing. 
Important:
  All configured polling intervals are rounded up to the closest multiple of 30. For example, if a polling 
interval is configured for 130 seconds, the system uses a polling interval of 150 seconds. 
Refer to the 
 and 
 commands for additional information 
on the system‘s support for thresholding. 
Example 
The following command configures the polling interval for the total MME session threshold polling duration value to 
600 seconds (10 minutes):