Cisco Cisco Packet Data Gateway (PDG) Fehlerbehebungsanleitung

Seite von 5213
FA Service Configuration Mode Commands   
▀  threshold reg-reply-error 
 
▄  Cisco ASR 5000 Series Command Line Interface Reference 
OL-22947-02   
threshold reg-reply-error 
Set an alarm or alert based on the number of registration reply errors per FA service. 
Product
 
PDSN, ASN GW, GGSN 
Privilege
 
Security Administrator, Administrator 
Syntax
 
Deletes the alert or alarm. 
Default: 0 
The high threshold number of registration reply errors that must be met or exceeded within the polling 
interval to generate an alert or alarm. It can be configured to any integer value between 0 and 100000. 
Important:
  You must enter a value between 1 and 100000 to trigger an alert/alarm. 
Default:0 
The low threshold number of registration reply errors that must be met or exceeded within the polling interval 
to clear an alert or alarm. It can be configured to any integer value between 0 and 100000. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Important:
  You must enter a value between 1 and 100000 to trigger an alert/alarm. 
Usage
 
Use this command to set an alert or an alarm when the number of registration reply errors is equal to or 
greater than a specified number of calls per second. 
Alerts or alarms are triggered for the number of registration reply errors on the following rules: 
 
Enter condition: Actual number of registration reply errors > High Threshold 
 
Clear condition: Actual number of registration reply errors £ Low Threshold 
Example