Cisco Cisco Packet Data Gateway (PDG) Fehlerbehebungsanleitung

Seite von 5213
  Global Configuration Mode Commands 
threshold aaa-retry-rate  ▀   
Cisco ASR 5000 Series Command Line Interface Reference  ▄  
 
  OL-22947-02 
threshold aaa-retry-rate 
Configures AAA retry rate thresholds for the system. 
Product
 
PDSN, GGSN, HA, ASN GW 
Privilege
 
Security Administrator, Administrator 
Syntax
 
Default: 5 
The high threshold percent of AAA request message retries that must be met or exceeded within the polling 
interval to generate an alert or alarm. 
high_thresh can be configured to any integer value between 0 and 100. 
Default: 5 
The low threshold percent of AAA request message retries that maintains a previously generated alarm 
condition. If the percentage of retries falls beneath the low threshold within the polling interval, a clear alarm 
will be generated. 
low_thresh can be configured to any integer value between 0 and 100. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Usage
 
AAA request message retry rate thresholds generate alerts or alarms based on the percentage of request 
messages (both authentication and accounting) that were retried during the specified polling interval. The 
percentage is based on a message count taken for all AAA authentication and accounting servers that the 
system is configured to communicate with. 
Alerts or alarms are triggered for request message retries based on the following rules: 
 
Enter condition: Actual retry percentage ³ High Threshold 
 
Clear condition: Actual retry percentage < Low Threshold 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval. 
Refer to the 
 command to configure the polling interval and the 
 command to enable thresholding for this value. 
Example 
The following command configures a AAA message retry rate high threshold percentage of 25 and a low threshold 
percentage of 10 for an system using the Alarm thresholding model: