Global Configuration Mode Commands
threshold dcca-bad-answer ▀
Cisco ASR 5000 Series Command Line Interface Reference ▄
OL-22947-02
threshold dcca-bad-answer
Configures the threshold for invalid or bad responses to the system from Diameter server.
Product
ECS
Privilege
Security Administrator, Administrator
Syntax
Disables the threshold for configured alarm and set the
and
values to 0.
Default: 0
The high threshold number of invalid messages or responses that must be met or exceeded within the polling
interval to generate an alert or alarm.
The number can be configured to any integer value between 0 and 1044000.
The high threshold number of invalid messages or responses that must be met or exceeded within the polling
interval to generate an alert or alarm.
The number can be configured to any integer value between 0 and 1044000.
Default: 0
The low threshold number of invalid messages/responses that maintains a previously generated alarm
condition. If the number of failures falls beneath the low threshold within the polling interval, a clear alarm
will be generated.
The number can be configured to any integer value between 0 and 1044000.
The low threshold number of invalid messages/responses that maintains a previously generated alarm
condition. If the number of failures falls beneath the low threshold within the polling interval, a clear alarm
will be generated.
The number can be configured to any integer value between 0 and 1044000.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
In the event that the system receives invalid message or response from Diameter server dcca-bad-answer is
generated.
DCCA bad answer messages size threshold generates alerts or alarms based on the number of invalid
response or messages received during the specified polling interval.
Alerts or alarms are triggered for DCCA bad answers based on the following rules:
generated.
DCCA bad answer messages size threshold generates alerts or alarms based on the number of invalid
response or messages received during the specified polling interval.
Alerts or alarms are triggered for DCCA bad answers based on the following rules:
Enter condition: Actual number of DCCA bad answer messages ³ High Threshold
Clear condition: Actual number of DCCA bad answer messages < Low Threshold
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end