Cisco Cisco Packet Data Gateway (PDG) Fehlerbehebungsanleitung

Seite von 5213
  Global Configuration Mode Commands 
threshold dcca-bad-answer  ▀   
Cisco ASR 5000 Series Command Line Interface Reference  ▄  
 
  OL-22947-02 
threshold dcca-bad-answer 
Configures the threshold for invalid or bad responses to the system from Diameter server. 
Product
 
ECS 
Privilege
 
Security Administrator, Administrator 
Syntax
 
Disables the threshold for configured alarm and set the 
 and 
 values to 0. 
Default: 0 
The high threshold number of invalid messages or responses that must be met or exceeded within the polling 
interval to generate an alert or alarm. 
The number can be configured to any integer value between 0 and 1044000. 
Default: 0 
The low threshold number of invalid messages/responses that maintains a previously generated alarm 
condition. If the number of failures falls beneath the low threshold within the polling interval, a clear alarm 
will be generated. 
The number can be configured to any integer value between 0 and 1044000. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the high threshold. 
Usage
 
In the event that the system receives invalid message or response from Diameter server dcca-bad-answer is 
generated. 
DCCA bad answer messages size threshold generates alerts or alarms based on the number of invalid 
response or messages received during the specified polling interval. 
Alerts or alarms are triggered for DCCA bad answers based on the following rules: 
 
Enter condition: Actual number of DCCA bad answer messages ³ High Threshold 
 
Clear condition: Actual number of DCCA bad answer messages < Low Threshold 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval. 
Example