Cisco Cisco Packet Data Gateway (PDG) Fehlerbehebungsanleitung

Seite von 5213
  Global Configuration Mode Commands 
threshold license  ▀   
Cisco ASR 5000 Series Command Line Interface Reference  ▄  
 
  OL-22947-02 
threshold license 
Configures thresholds for session license utilization for the system. 
Product
 
All 
Privilege
 
Security Administrator, Administrator 
Syntax
 
Default: 10 
The low threshold session license utilization percentage that must be met or exceeded within the polling 
interval to generate an alert or alarm. 
 can be configured to any integer value between 0 and 100. 
Default: 10 
The high threshold session license utilization percentage that maintains a previously generated alarm 
condition. If the utilization percentage rises above the high threshold within the polling interval, a clear alarm 
will be generated. 
 can be configured to any integer value between 0 and 100. 
Important:
  This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm 
model, the system assumes it is identical to the low threshold. 
Usage
 
Session license utilization thresholds generate alerts or alarms based on the utilization percentage of all 
session capacity licenses during the specified polling interval. 
As described in Chapter 7 of the Administration and Configuration Guide, the system uses session capacity 
license to dictate the maximum number of simultaneous sessions that can be supported. There are multiple 
session types that require licenses (i.e. Simple IP, Mobile IP, L2TP, etc.). Although, a single threshold is 
configured for all session types, alerts or alarms can be generated for each type. 
Alerts or alarms are triggered for session license utilization based on the following rules: 
 
Enter condition: Actual session license utilization percentage per session type £ Low Threshold 
 
Clear condition: Actual session license utilization percentage per session type > High Threshold 
If a trigger condition occurs within the polling interval, the alert or alarm will not be generated until the end 
of the polling interval. 
Refer to the 
 command to configure the polling interval and the 
 command to enable thresholding for this value. 
Example