Cisco Cisco Packet Data Gateway (PDG) Fehlerbehebungsanleitung

Seite von 192
  PDN Gateway Overview 
Features and Functionality - Base Software  ▀   
Cisco ASR 5000 Series Packet Data Network Gateway Administration Guide  ▄  
 
  OL-22985-01 
The system supports Threshold Crossing Alerts for certain key resources such as CPU, memory, IP pool addresses, etc. 
With this capability, the operator can configure threshold on these resources whereby, should the resource depletion 
cross the configured threshold, a SNMP Trap would be sent. 
The following thresholding models are supported by the system: 
 
 
Alert: A value is monitored and an alert condition occurs when the value reaches or exceeds the configured high 
threshold within the specified polling interval. The alert is generated then generated and/or sent at the end of 
the polling interval. 
 
Alarm: Both high and low threshold are defined for a value. An alarm condition occurs when the value reaches 
or exceeds the configured high threshold within the specified polling interval. The alert is generated then 
generated and/or sent at the end of the polling interval. 
Thresholding reports conditions using one of the following mechanisms: 
 
SNMP traps: SNMP traps have been created that indicate the condition (high threshold crossing and/or clear) of 
each of the monitored values. 
Generation of specific traps can be enabled or disabled on the chassis. Ensuring that only important faults get 
displayed. SNMP traps are supported in both Alert and Alarm modes. 
 
Logs: The system provides a facility called threshold for which active and event logs can be generated. As with 
other system facilities, logs are generated Log messages pertaining to the condition of a monitored value are 
generated with a severity level of WARNING. 
Logs are supported in both the Alert and the Alarm models. 
 
Alarm System: High threshold alarms generated within the specified polling interval are considered 
―outstanding‖ until a the condition no longer exists or a condition clear alarm is generated. ―Outstanding‖ 
alarms are reported to the system's alarm subsystem and are viewable through the Alarm Management menu in 
the Web Element Manager. 
The Alarm System is used only in conjunction with the Alarm model. 
Important:
  For more information on threshold crossing alert configuration, refer to the Thresholding 
Configuration Guide
 
ANSI T1.276 Compliance 
ANSI T1.276 specifies security measures for Network Elements (NE). In particular it specifies guidelines for password 
strength, storage, and maintenance security measures. 
ANSI T1.276 specifies several measures for password security. These measures include: 
 
 
Password strength guidelines 
 
Password storage guidelines for network elements 
 
Password maintenance, e.g. periodic forced password changes 
These measures are applicable to the ASR 5000 and the Web Element Manager since both require password 
authentication. A subset of these guidelines where applicable to each platform will be implemented. A known subset of 
guidelines, such as certificate authentication, are not applicable to either product. Furthermore, the platforms support a