Cisco Cisco Packet Data Gateway (PDG) Fehlerbehebungsanleitung

Seite von 322
  Troubleshooting the  System 
Detecting Faulty Hardware Using Component LEDs  ▀   
Cisco ASR 5000 Series System Administration Guide  ▄  
 
  OL-22969-02 
Color
 
Description
 
Troubleshooting
 
Red
 
Failures Detected
 
 
Check the RUN/FAIL LEDs for all installed application cards, and line cards. If any are red 
or off, refer to the troubleshooting information in this chapter pertaining to that device. 
 
Refer to one or more of the following to help analyze this problem: 
 
The Monitoring Hardware Status chapter in this reference for show commands; the outputs 
of which will assist in further determining the problem. 
 
The Configuring and Viewing System Logs chapter in this reference for information on 
configuring specific types of logging information and how to view logs. 
 
SNMP MIB Reference for information on associated status and alarm conditions. 
None
 
Card is not 
receiving power
 
Verify that the RUN/FAIL LED is green. If so, the card is receiving power and POST test results are 
positive. If it is off, refer to the SMC RUN/FAIL LED States section of this chapter for 
troubleshooting information. 
 
 
SMC Service LED States 
The Service LEDs on the SMCs indicate that the system requires maintenance or service (e.g. the system could not 
locate a a valid software image at boot-up, or a high temperature condition exists). 
This LED is off during normal operation. 
The possible states for this LED are described in the following table. If the LED is not green, use the troubleshooting 
information in the table to diagnose the problem. 
Table 31. 
SMC Service LED States 
Color
 
Description
 
Troubleshooting
 
Yellow
 
System requires maintenance (fan 
filter, temperature warning, PFU 
outage etc.)
 
Refer to one or more of the following to help analyze this problem: 
 
The Monitoring Hardware Status chapter in this reference for show 
commands; the outputs of which will assist in further determining 
the problem. 
 
The Configuring and Viewing System Logs chapter in this reference 
for information on configuring specific types of logging information 
and how to view logs. 
 
SNMP MIB Reference for information on associated status and alarm 
conditions. 
None
 
Card is not receiving power
 
No maintenance needed.