Cisco Cisco Packet Data Gateway (PDG) Fehlerbehebungsanleitung

Seite von 322
Troubleshooting the  System   
▀  Detecting Faulty Hardware Using Component LEDs 
 
▄  Cisco ASR 5000 Series System Administration Guide 
OL-22969-02   
Color
 
Description
 
Troubleshooting
 
Red
 
Card powered with 
error(s) detected
 
Errors were detected during the POSTs. It is likely that the errors were logged to the system's 
command line interface during the boot process. 
Refer to the Monitoring the System chapter of this reference for information on determining the 
status of system hardware components. 
None
 
Card powered with 
error(s) detected
 
 
Verify that the POWER LEDs on the PFUs are green. If they are not, refer to the 
Checking the LED on the PFU(s) section in this chapter for troubleshooting 
information. 
 
Verify that the power source is supplying ample voltage and current to the chassis. 
 
Verify that the card is properly installed per the instructions in the Hardware 
Installation and Administration Guide
 
If all of the above suggestions have been verified, it is possible that the SPIO is not 
functional. Please contact your service representative. 
 
 
RCC Active LED States 
The Active LED on the RCC indicates that the card is being used. For normal operation, this LED should be off on both 
RCCs. 
 
The possible states for this LED are described in the following table. If the LED is not green, use the troubleshooting 
information in the table to diagnose the problem. 
Table 47. 
RCC Active LED States 
Color
 
Description
 
Troubleshooting
 
Green
 
Card is active
 
The RCC is actively routing traffic from a line card installed behind a PAC/PSC that has 
failed to a redundant PAC/PSC. 
The RCC installed in chassis slot 40 processes traffic for the line cards in chassis slots 17 
through 23 and 26 through 32. The RCC installed in chassis slot 41 processes traffic for the 
line cards in slots 33 through 39 and 42 through 48. 
Refer to either the Checking the LEDs on the PAC(s) or Checking the LEDs on the PSC(s) 
section of this chapter to determine which PAC/PSC has failed. 
None
 
Card is not receiving 
power OR Card in 
Standby Mode
 
 
Verify that the RUN/FAIL LED is green. If so, the card is receiving power and 
POST test results are positive. If it is off, refer to the RCC RUN/FAIL LED States 
section of this chapter for troubleshooting information. 
 
Check the state of the Standby LED. If it is green, the card is in standby mode. This 
is the normal operating mode.