show card diag
Table 215.
show card diag
Command Output Descriptions
Field
Description
Counters
Displays boot counter information for the card. The following counters are reported:
Successful warm boots: Warm boots occur upon a software reset of the card.
Successful cold boots: Cold boots occur when the card experiences a hardware reboot.
Total boot attempts: This is the sum of successful and unsuccessful warm and cold boots. If this
number is not equal to the total number of successful warm boots and the number of successful cold
boots, then boot failures have occurred. This situation may indicate a problem with this card that
requires further investigation.
number is not equal to the total number of successful warm boots and the number of successful cold
boots, then boot failures have occurred. This situation may indicate a problem with this card that
requires further investigation.
In Service Date: Timestamp indicating when this card was placed in service.
Each of the above counters provide a timestamp indicating the most recent occurrence.
NOTE: Counters are not displayed for line card diagnostics.
NOTE: Counters are not displayed for line card diagnostics.
Status
Status is reported for the following items:
IDEEPROM Magic Number: Indicates whether or not the device map has been initialized. The ID
EEPROM device stores hardware, diagnostic and software configuration data.
EEPROM device stores hardware, diagnostic and software configuration data.
Boot Mode: Displays the current boot mode. – Normal (boot to StarOS, default mode), Extended
diagnostics or Diagnostic CLI.
diagnostics or Diagnostic CLI.
Card Diagnostics: Indicates the current status of the card's internal diagnostics. The two possible
states are: Pass (all diagnostics passed) and Failed one or more diagnostics did not pass).
states are: Pass (all diagnostics passed) and Failed one or more diagnostics did not pass).
Current Failure: Indicates any failure that is currently being reported by this card. If no failures were
detected, this item will display None.
detected, this item will display None.
Last Failure: Indicates the last failure reported by this card since its event log was last cleared.
Card Usable: Indicates whether or not the card is usable. “Usability” is based on the operational state
of the card (active, standby, or offline), whether or not the Administrative state is enabled (the card is
configured for use via software), and whether or not the card’s interlock switch is locked. Either a Yes
or a No will be displayed.
of the card (active, standby, or offline), whether or not the Administrative state is enabled (the card is
configured for use via software), and whether or not the card’s interlock switch is locked. Either a Yes
or a No will be displayed.
Last Reset Cause: Indicates the cause for the last reset of this card.
Note: This field only appears if a card reset has occurred.
Boot/Diag Log
ASR 5000 only
ASR 5000 only
Displays the contents of the boot and diagnostics log.
NOTE: The boot and diagnostic log contents are not displayed for line card diagnostics.
NOTE: The boot and diagnostic log contents are not displayed for line card diagnostics.
Error Log
ASR 5000 only
ASR 5000 only
Displays the contents of the error log.
NOTE: The error log contents are not displayed for line card diagnostics.
NOTE: The error log contents are not displayed for line card diagnostics.
Current
Environment
Not displayed
for QvPC
Environment
Not displayed
for QvPC
Displays the results for the following measurements:
Temperature measurements: Indicates the current operating temperatures and provides the
maximum safe temperature for comparison.
maximum safe temperature for comparison.
Voltage measurements: Indicates the current input status for the various DC sources and provides the
acceptable upper and lower limits for comparison.
acceptable upper and lower limits for comparison.