Cisco Cisco Packet Data Gateway (PDG)

Seite von 361
Troubleshooting   
▀  Detecting Faulty Hardware 
 
 
▄  ASR 5500 System Administration Guide, StarOS Release 17 
188 
   
SSC Redundancy LED States 
The Redundancy LED on the SSC indicates that software is loaded on the card, but it is serving as a standby component. 
SSC support 1:1 redundancy; the Redundancy LED should be green on the other SSC for normal system operation. 
The possible states for this LED are described in the following table. If the LED is not green, use the troubleshooting 
information in the table to diagnose the problem. 
Table 30.  SSC Redundancy LED States 
Color
 
Description
 
Troubleshooting
 
Green
 
Card is in standby mode
 
None needed. The other SSC should be in Standby mode. 
Amber
 
Card is not backed up by the 
standby SSC.
 
Check the status of the other SSC. If one it has failed or has been removed 
from the chassis, the system can continue to function but redundancy is 
compromised.
 
Refer to Monitoring the System for information on determining the status of the 
SSC and system software processes.
 
Blinking 
Amber
 
Tasks or processes being migrated 
from the active SSC to the 
standby SSC.
 
Refer to Monitoring the System for information on determining the status of the 
SSC and system software processes.
 
None
 
Card is not receiving power. 
OR 
Card has failed. 
Verify that the Run/Fail LED is green. If so, the card is receiving power and 
POST results are positive. If it is off, refer to the SSC Run/Fail LED States 
section for troubleshooting information.
 
 
SSC System Status LED States 
The System Status LED on the SSC indicates the that there is a loss of service somewhere in the system. If this LED is 
red, the system requires maintenance or service (for example, the system could not locate a a valid software image at 
boot-up, or a high temperature condition exists). 
The possible states for this LED are described in the following table. If the LED is not green, use the troubleshooting 
information also provided to diagnose the problem. 
Table 31.  SSC System Status LED States 
Color
 
Description
 
Troubleshooting
 
Green
 
System is operating normally
 
None required.
 
Red
 
The system has experienced a 
loss of service.
 
Refer to Monitoring the System for information on determining the status of system 
hardware and software processes.
 
None
 
Card is not receiving power
 
Verify that the Run/Fail LED is green. If so, the card is receiving power and POST 
results are positive. If it is off, refer to the SSC Run/Fail LED States section for 
troubleshooting information.