Cisco Cisco Packet Data Gateway (PDG)

Seite von 362
Management Settings   
▀  SNMP Support 
 
 
▄  ASR 5500 System Administration Guide, StarOS Release 16 
80 
   
Notes: 
 
The system contact is the name of the person to contact when traps are generated that indicate an error 
condition. 
 
An snmp community string is a password that allows access to system management information bases (MIBs). 
 
The system can send SNMPv1, SNMPv2c, or SNMPv3 traps to numerous target devices. However, WEM can 
only process SNMP version 1 (SNMPv1) and SNMP version 2c (SNMPv2c) traps. If the SNMP target you are 
configuring is the WEM application, use the snmp target command to configure use of version 1 or version 
2c. Issue this command as many times as you need to configure multiple targets. If you configure multiple 
targets, generated alarms are sent to every configured target. 
 
The snmp notif-threshold command configures the number of SNMP notifications that need to be generated for 
a given event and the number of seconds in the monitoring window size (default = 300), before the notification 
is propagated to the SNMP users (default = 100). 
 
The snmp engine-id local command is optional. It is only required if your network requires SNMP v3 support. 
The engine ID uniquely identifies the SNMP engine and associated SNMP entities, thus providing a security 
association between the two for the sending and receiving of data. 
 
The snmp user name is for SNMP v3 and is optional. There are numerous keyword options associated with this 
command. 
 
Use the snmp mib command to enable other industry standard and Cisco MIBs. By default only the STARENT-
MIB is enabled. 
Important:
  SNMPv3 traps are not supported by the WEM application. 
Verifying SNMP Parameters 
Step 1 
Run the show snmp server command to verify that the SNMP server information is correctly configured. The 
following displays a sample output of this command. 
SNMP Server Configuration: 
  Server State             : enabled  
  SNMP Port                : 161 
  sysLocation              : chicago  
  sysContact               : admin 
  authenticationFail traps : Enabled 
  EngineID                 : 123456789 
  Alert Threshold          : 100 alerts in 300 seconds  
  Alert Low Threshold      : 20 alerts in 300 seconds  
SNMP Agent Mib Configuration: 
                         STARENT-MIB : Enabled  
                              IF-MIB : Disabled  
                          ENTITY-MIB : Disabled  
                    ENTITY-STATE-MIB : Disabled  
                  ENTITY-SENSORE-MIB : Disabled  
                  HOST-RESOURCES-MIB : Disabled  
   CISCO-MOBILE-WIRELESS-SERVICE-MIB : Disabled  
            CISCO-ENTITY-DISPLAY-MIB : Disabled  
                   CISCO-PROCESS-MIB : Disabled  
         CISCO-ENTITY-FRU-CONTROL-MIB : Disabled