  System Settings 
Configuring Line Card and SPIO Port Redundancy  ▀   
 
ASR 5000 System Administration Guide, StarOS Release 16  ▄  
 
   
73 
Caution:
  A preference cannot be configured in normal redundancy mode. Attempting to do so will produce an 
error message from the cli command. 
Save the configuration as described in the Verifying and Saving Your Configuration chapter. 
Verifying Line Card and SPIO Port Redundancy Auto-Recovery 
Verify port information by entering the following command 
show port info slot#/port# 
slot# is the chassis slot number of the line card on which the physical port resides. 
port# is the physical port on the line card. 
The following shows a sample output of this command for port 1 on the LC in slot 17: 
[local]host_nameshow port info 17/1 
Port: 17/1 
  Port Type               : 1000 Ethernet 
  Role                    : Service Port 
  Description             : (None Set) 
  Controlled By Card      : 1 (Packet Services Card 2) 
  Redundancy Mode         : Port Mode 
  Framing Mode            : Unspecified 
  Redundant With          : 33/1 
  Preferred Port          : Revertive to port 17/1 
  Physical ifIndex        : 285278208 
  Administrative State    : Enabled 
  Configured Duplex       : Auto 
  Configured Speed        : Auto 
  MAC Address             : 00-05-47-01-11-00 
  Boxer Interface TAP     : None 
  Link State              : Up 
  Link Duplex             : Unknown 
  Link Speed              : Unknown 
  Flow Control            : Disabled 
  Link Aggregation Group  : None 
  Logical ifIndex         : 285278209  
  Operational State       : Down, Active  
  SFP Module              : 285278209