Cisco Cisco Packet Data Gateway (PDG)
HNB-CS Network Configuration Mode Commands
offload-msc ▀
Command Line Interface Reference, StarOS Release 16 ▄
6237
offload-msc
Provisions the HNB-GW to enable or disable the exclusion of a particular primary MSC node during an NAS Node
Selection Function (NNSF) procedure when it needs to be offloaded while using Iu-Flex functionality on the HNB-GW.
Selection Function (NNSF) procedure when it needs to be offloaded while using Iu-Flex functionality on the HNB-GW.
Product
HNB-GW
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration > HNB-CS Network Configuration
configure > cs-network cs_instance
Entering the above command sequence results in the following prompt:
[local]host_name(config-cs-network-instance_id)#
Syntax
[ no ] offload-msc point-code msc_point_code
no
Removes the specified primary MSC point code from the exclusion list for NNSF function on HNB-GW and
re-enables the inclusion of the primary MSC to be considered by HNB-GW.
re-enables the inclusion of the primary MSC to be considered by HNB-GW.
point-code
msc_point_code
Specifies the SS7 address of the primary MSC in the CS network to be excluded for NNSF function on HNB-
GW when it needs to be offloaded via Iu-Flex functionality.
GW when it needs to be offloaded via Iu-Flex functionality.
point_code
is an SS7 point code in dotted-decimal ###.###.### or 8-digit decimal ######## format.
Only one instance of this primary MSC point code can be mapped with one CS core network id.
Usage
Use this command to provision the HNB-GW to enable or disable the exclusion of the primary MSC node
when it needs to be offloaded.
When this command is enabled for exclusion of primary MSC node during NNSF function in HNB-GW, the
HNB-GW excludes the particular node from being considered.
User can re-enable the inclusion of the primary MSC node to be considered for NNSF functionality by
when it needs to be offloaded.
When this command is enabled for exclusion of primary MSC node during NNSF function in HNB-GW, the
HNB-GW excludes the particular node from being considered.
User can re-enable the inclusion of the primary MSC node to be considered for NNSF functionality by
no
offload-msc point-code
command.
Important:
Offload check is only for the primary point code and NOT for the backup point code.
This command can be used for planned maintenance as well.
Example
The following command configures the HNB-GW to exclude the primary MSC point code
1.2.3
from being
considered in NSSF function for Iu-Flex support:
offload-msc point-code 1.2.3