Cisco Cisco Packet Data Gateway (PDG)

Seite von 465
  S-GW CDR Field Descriptions 
CDR Fields  ▀   
 
GTPP Interface Administration and Reference, StarOS Release 18  ▄  
 
   
409 
Format 
Octet String
 
Length 
16 bytes
 
Local Record Sequence Number 
This field contains a unique sequence number associated with the NodeId field and independent of the bearer context. For 
each Node ID, this number with range 1..4294967295 is allocated sequentially for each CDR. This along with a Node ID 
uniquely identifies a CDR. For SGW-CDRs, this field is included only when the command 
gtpp attribute local-
record-sequence-number
 is configured.
 
Format 
Octet String
 
Length 
1-5 bytes
 
Low Access Priority Indicator 
This field indicates if the PDN connection has a low priority, i.e. for Machine Type Communication.
 
Important:
  This attribute field is currently available only in custom24 and custom35 GTPP dictionaries for 
SGW-CDRs when the CLI command “
gtpp attribute lapi
” is configured in GTPP Server Group Configuration 
mode. 
Format 
Null
 
Length 
0 Byte
 
MS Time Zone 
The “Time Zone” IE that the MME may provide to the S-GW during the PDN context activation/modification procedure.
 
Format 
Octet String
 
Length 
2 bytes
 
Node ID 
This field contains an identifier string for the node that had generated the CDR. 
 
The NodeID field is a printable string of the ndddSTRING format:
 
n: The first digit is the Sessmgr restart counter having a value between 0 and 7.