Cisco Cisco Packet Data Gateway (PDG)

Seite von 424
  S-GW CDR Field Descriptions 
CDR Fields  ▀   
 
GTPP Interface Administration and Reference, StarOS Release 16  ▄  
 
   
375 
SGW Address Used 
This field is the serving S-GW IP address for the Control Plane. If both an IPv4 and an IPv6 address of the S-GW is available, 
the S-GW includes the IPv4 address in the CDR. This is a choice attribute and the CDR can contain the binary format or the 
ASCII format in the CDR.
 
Format 
Octet string
 
Length 
The length can vary based on whether the encoded IP address is IPv4 or IPv6.
 
SGW IPv4 Binary Address 
This field is the serving control plane S-GW IPv4 address on the S5 interface.
 
Format 
Octet string
 
Length 
4 bytes
 
SGW IPv6 Binary Address 
This field is the serving control plane S-GW IPv6 address on the S5 interface.
 
Format 
Octet string
 
Length 
16 bytes
 
SGW Change 
This field is present only in the SGW-CDR to indicate that this is the first record after an S-GW change. In this case, it is set 
to TRUE (“FF”)
 
Format 
Boolean
 
Length 
1 byte
 
Start Time 
This field contains the time when the IP-CAN session starts at the S-GW/P-GW, available in the CDR for the first bearer in an 
IP-CAN session.
 
The timestamp is determined based on the internal timer which has an accuracy of 10ms. Depending on the 
configured mechanism this is translated into the timestamp which only shows the full seconds.
 
The format is shown below.