  ECS Changes in Release 17 
ECS Enhancements for 17.1  ▀   
 
Release Change Reference, StarOS Release 17  ▄  
 
   
135 
Feature Changes 
Extending FDR/EDR and UDR for NEMO Sessions
 
As part of this feature, these configurable attributes are added to FDR/EDRs and UDRs to support the NEMO sessions. 
 
sn-subscriber-ipv4-address 
 
sn-subscriber-ipv6-address 
 
sn-vrf-name 
 
nemo-prefix-list 
 
num-nemo-prefix 
Important:
  The “nemo-prefix-list” and “num-nemo-prefix” attributes are available only with NEMO license. 
The attributes “sn-vrf-name”, “nemo-prefix-list” and “num-nemo-prefix” are customer-specific. 
These attributes will not be present in FDR/EDRs and UDRs unless explicitly configured. An additional trigger “nemo-
prefix-update” is added for UDR generation on receiving a NEMO update event. 
These attributes are required to populate the VRF-name and NEMO MR prefixes in UDR. The format in which these 
will be populated in UDRs is “<VRF-name>:<NEMO MR Prefix>”.  
Command Changes 
attribute
 
A new attribute “sn-vrf-name” is added to EDR format to support NEMO sessions. 
configure 
  require active-charging 
  active-charging service service_name 
     edr-format format_name 
         [ no ] attribute sn-vrf-name priority priority_value 
        end 
Notes: 
 
sn-vrf-name
: This attribute indicates the VRF name associated with the base session of NEMO. This is a 
customer-specific attribute. 
attribute
 
Five new attributes are added to UDR format to support NEMO sessions. 
configure 
  require active-charging