Feature Changes
Installation of PCRF Bound Predefined Rule Based on Access Side Signaling
Previous Behavior: If a PCRF bound predefined rule is sent for installation, there was no check to determine if there
was any access side signaling that was pending for the same predefined rule.
was any access side signaling that was pending for the same predefined rule.
New Behavior: A check is now made available to verify if the predefined rule exists in pending rules list before
binding it to the bearer. If the rule exists, a failure is indicated to PCRF.
binding it to the bearer. If the rule exists, a failure is indicated to PCRF.
Customer Impact: PCRF bound predefined rules can fail to get installed/updated if there is any access side signaling
pending for the same rule.
pending for the same rule.
CSCul50221 - P4: show active-charging service all prints ICMP w/out v4/V6
details
Applicable Products: P-GW
Feature Changes
Change in display of ‘show active-charging service all’ command
Previous Behavior: The CLI command
show active-charging service all
was printing the message “ICMP
Flow Idle Timeout : 300 (secs)” twice, once for IPv4 and once for IPv6.
New Behavior: The CLI command
show active-charging service all
now prints the message “ICMP Flow
Idle Timeout : 300 (secs)” only once.
Command Changes
show active-charging service all
The CLI command
show active-charging service all
now prints the message “ICMP Flow Idle Timeout: 300