  System Changes in Release 17 
System and Platform Enhancements for Release 17.0  ▀   
 
Release Change Reference, StarOS Release 17  ▄  
 
   
631 
Command Changes 
guard-timer
 
This new SRP Configuration mode command configures the redundancy-guard-period and monitor-damping-period for 
SRP service monitoring. 
Use these guard timers to ensure that local failures, such as card reboots and task restarts, do not result in ICSR events 
which can be disruptive. 
configure 
   context context_name 
      service-redundancy-protocol variable 
         guard-timer { aaa-switchover-timers { damping-period seconds | guard-period 
seconds } | diameter-switchover-timers { damping-period seconds | guard-period seconds 
| srp-redundancy-timers
 { aaa { damping-period seconds | guard-period seconds } | bgp 
damping-period
 seconds | guard-period seconds } | diam  { damping-period seconds | guard-
period
 seconds } } 
         end 
Notes: 
 
aaa-switchover-timers – sets timers that prevent back-to-back ICSR switchovers due to an AAA failure (post 
ICSR switchover) while the network is still converging. 
 
damping-period – configures a delay time to trigger an ICSR switchover due to a monitoring failure 
within the guard-period. 
 
guard-period – configures the local-failure-recovery network-convergence timer. 
 
diameter-switchover-timers – sets timers that prevent a back-to-back ICSR switchover due to a Diameter 
failure (post ICSR switchover) while the network is still converging. 
 
damping-period – configures a delay time to trigger an ICSR switchover due to a monitoring failure 
within the guard-period. 
 
guard-period – configures the local-failure-recovery network-convergence timer. 
 
srp-redundancy-timers – sets timers that prevent an ICSR switchover while the system is recovering from a 
local card-reboot/critical-task-restart failure. 
 
aaa – local failure followed by AAA monitoring failure 
 
bgp – local failure followed by BGP monitoring failure 
 
diam – local failure followed by Diameter monitoring failure 
CSCum87759 - Configurable MinRtAdvInterval 
Applicable Products: All products that support ICSR 
Related CDETS ID: CSCum80398