Cisco Cisco Packet Data Gateway (PDG)
StarOS Management Operations
Upgrading StarOS ▀
VPC-VSM System Administration Guide, StarOS Release 19 ▄
107
Reboot StarOS
Reboot StarOS by entering the following command:
[local]host_name# reload [-noconfirm]
As StarOS reboots, it loads the new StarOS image and its corresponding CLI configuration file using the new boot stack
entry configured earlier.
entry configured earlier.
After the reboot is completed, establish a CLI session and enter the show version command to verify that the active
software version is correct.
software version is correct.
Verify the Running Software Version
After StarOS has successfully booted, verify that the new StarOS version is running by executing the Exec mode show
version command.
version command.
[local]host_name# show version
Restoring the Previous Software Image
If for some reason you need to undo the upgrade, perform the upgrade again except:
Specify the locations of the upgrade software image and configuration files.
then
Specify the locations of the original software image and configuration files.
Upgrading ICSR
The procedure for upgrading primary and backup ICSR instances is described in the Interchassis Session Recovery
chapter. Essentially the procedure requires upgrading the primary and standby VPCs using the off-line method while
each is in standby mode.
chapter. Essentially the procedure requires upgrading the primary and standby VPCs using the off-line method while
each is in standby mode.