Cisco Cisco Packet Data Gateway (PDG)

Seite von 360
Interchassis Session Recovery   
▀  StarOS Updates in an ICSR Configuration 
 
 
▄  VPC-VSM System Administration Guide, StarOS Release 19 
272 
   
 
  
 
  
 
  
 
  
 
  
 
  
 
  
Initiating an SRP Switchover 
An SRP switchover places the backup VPC-VSM instance in standby mode and makes the primary instance active. The 
primary instance is now processing sessions with the upgraded software. 
Step 1 
Initiate the switchover by shutting down the HSRP interface being monitored by SRP. All existing sessions will be 
migrated to the primary instance and it begins servicing new session requests. Allow the switchover process to 
complete. 
Step 2 
On the backup instance, run the show srp info command. Chassis State should indicate Standby when switchover is 
complete.  
Step 3 
On the primary instance, confirm the switchover is complete by running the show srp info command. Chassis State 
should indicate Active when switchover is complete. 
Checking AAA Monitor Status 
If your network deployment requires communication with AAA servers, check the status of communication with AAA 
servers as described in 
  
Making Test Calls 
After verifying the VPC-VSM instance state and migrating subscribers, perform new call testing to make sure calls are 
successful. 
Fallback Procedure 
To revert to the previous configuration and software build, perform the following steps as a user with administrative 
privileges. 
Step 1 
Run the Exec mode show boot command. The topmost lowest numbered entry of the displayed output should be the 
new configuration with the new software build. The second topmost entry should be the backup configuration. 
Step 2 
Remove the topmost boot entry <n>. 
[local]host_nameconfig 
[local]host_name(config)# no boot system priority n