Cisco Cisco Packet Data Gateway (PDG)
SNMP Configuration
▀ Verifying SNMP Parameters
▄ VPC-VSM System Administration Guide, StarOS Release 19
72
Verifying SNMP Parameters
Step 1
Run the show snmp server command to verify that the SNMP server information is correctly configured. The
following displays a sample output of this command.
following displays a sample output of this command.
SNMP Server Configuration:
Server State : enabled
SNMP Port : 161
sysLocation : chicago
sysContact : admin
authenticationFail traps : Enabled
EngineID : 123456789
Alert Threshold : 100 alerts in 300 seconds
Alert Low Threshold : 20 alerts in 300 seconds
SNMP Agent Mib Configuration:
STARENT-MIB : Enabled
IF-MIB : Disabled
ENTITY-MIB : Disabled
ENTITY-STATE-MIB : Disabled
ENTITY-SENSORE-MIB : Disabled
HOST-RESOURCES-MIB : Disabled
CISCO-MOBILE-WIRELESS-SERVICE-MIB : Disabled
CISCO-ENTITY-DISPLAY-MIB : Disabled
CISCO-ENTITY-FRU-CONTROL-MIB : Disabled
CISCO-ENTITY-REDUNDANCY-MIB : Disabled
CISCO-IP-LOCAL-POOL-MIB : Disabled
CISCO-PROCESS-MIB : Disabled
CISCO-FLASH-MIB : Disabled
CISCO-IPSEC-FLOW-MONITOR-MIB : Disabled
CISCO-ENHANCED-IPSEC-FLOW-MIB : Disabled