Cisco Cisco ONS 15216 (EDFA3) Metropolitan Regional DWDM System Installationsanleitung

Seite von 28
The port connections between the odd patch panel (15216-MD-40, 15216-EF-40, or 15216-MD-48), ONS 15216-MD-48-CM
interleaver and deinterleaver pluggable, and the even patch panel (15216-MD-40, 15216-EF-40, or 15216-MD-48) are established
as follows:
• COM-TX port of the odd patch panel and ODD-RX port of the interleaver and deinterleaver pluggable.
• COM-RX port of the odd patch panel and ODD-TX port of the interleaver and deinterleaver pluggable.
• COM-TX port of the even patch panel and EVEN-RX port of the interleaver and deinterleaver pluggable.
• COM-RX port of the even patch panel and EVEN-TX port of the interleaver and deinterleaver pluggable.
Optical Interconnections for ONS 15216-MD-48-CME
The optical interconnections between the odd patch panel, ONS 15216-MD-48-CME coupler and splitter pluggable and the even
patch panel is shown in the following figure:
Figure 5: ONS 15216-MD-40 and ONS 15216-EF-40 Patch Panel Interconnection with ONS 15216-MD-48-CME Coupler and Splitter Pluggable
Figure 6: ONS 15216-MD-48 Patch Panel Interconnection with ONS 15216-MD-48-CME Coupler and Splitter Pluggable
6