Cisco Cisco 1 GHz GainStar Node Installationsanleitung

Seite von 92
 
Chapter 3        Balancing and Setup 
 
 
 
36 
OL-31947-02 
Preparing for Forward Path Balancing 
Before You Begin 
Before you begin balancing, it is important to review and understand the following 
information. This information will show you which balancing process is appropriate 
for your GainStar Mini Node. 
Before balancing, make sure you have configured the mainboard according to the 
specifications in your design print and that the GainStar Mini Node has warmed up 
for approximately one hour. The table below shows the items needed for balancing. 
You need a ... 
To ... 
copy of the design print 
determine expected input and output signal 
levels. 
torque wrench with 1/2-inch socket 
open and close the system amplifier housing. 
spectrum analyzer or signal analysis 
meter capable of working with 
frequencies up to the highest design 
frequency 
determine absolute and relative signal levels. 
test point probe (part number 1010409) 
access the test points. 
75 ohm coaxial cable with F-connectors 
on each end 
connect the test point probe to the test 
equipment.