Cisco Cisco D9804 Multiple Transport Receiver Installationsanleitung
Chapter 6 Service and Maintenance
150
78-4042990-01 Rev B
Warnings
The following table shows an alphabetical list of the available warning messages and their
default status.
default status.
Message
Set/Clear Message
Cause/Remedy
Temperature
Warning
Warning
Temperature over Warning
threshold
threshold
Cause: The internal temperature is
approaching the safe temperature limit
due to fan failure, excessively high
ambient temperature or blocked air flow. If
not corrected, this will eventually cause a
Temperature Alarm.
approaching the safe temperature limit
due to fan failure, excessively high
ambient temperature or blocked air flow. If
not corrected, this will eventually cause a
Temperature Alarm.
Remedy: Fix the faulty fan, reduce the air
temperature and/or ensure that there are
no air flow restrictions.
temperature and/or ensure that there are
no air flow restrictions.
Note: The MTR will shut down when the
air temperature exceeds the shutdown
threshold (65°C).
air temperature exceeds the shutdown
threshold (65°C).
FPGA Code
Version
Version
FPGA code ver mismatch:
HDR=X##.##.##
BIN=X##.##.##.X
HDR=X##.##.##
BIN=X##.##.##.X
Cause: The wrong FPGA code version
exists in the memory.
exists in the memory.
Remedy: Reboot the unit to attempt to
clear the problem.
clear the problem.
IBC Carrier Info
Fault
Fault
Table Empty
Cause: CIT Table is empty.
Remedy: The message will be cleared once
the correct IBC data is received.
the correct IBC data is received.
IBC Data Lost
IBC Port RF-# (# is RF port
number)
number)
Cause: One of the ASI ports received
incorrect IBC data.
incorrect IBC data.
Remedy: The message will be cleared once
the correct IBC data is received.
the correct IBC data is received.
IBC Source
Changed
Changed
IBC Port RF-# (# is RF port
number)
number)
Cause: When IBC source changes.
Remedy: The message will be cleared once
the correct IBC data is received.
the correct IBC data is received.
IBC Transp Info
Fault
Fault
Table Empty
Cause: CTT Table is empty.
Remedy: The message will be cleared once
the correct IBC data is received.
the correct IBC data is received.