Specifications 
 
Electrical 
Units 
 
Notes 
Max. AC Through Current (continuous) 
Amps 
15 
 
Max. AC Through Current (surge) 
Amps 
25 
 
Component DC Power Consumption (typical) 
 
@ +24 VDC 
@ +15 VDC 
@ -6 VDC 
Launch Amplifier with 5 PHD hybrids 
Amps 2.1 
 
Standard (1X) Reverse Router Module 
Amps 
0.07 
 
Dual Segmentation (2X) Reverse Router Module 
Amps 
0.13 
 
Quad Segmentation (4X) Reverse Router Module 
Amps 
 
0.25 
 
 
Forward Redundancy Module 
Amps 
0.04 
 
 
 
Forward Narrowcast Module 
Amps 
0.04 
 
 
 
Status Monitoring Transponder 
Amps 
0.15 
 
Standard Optical Receiver Amps 
0.25 
0.01 
0.035 
 
High Gain Optical Receiver 
Amps 
0.35 
0.01 
0.035 
 
6940/44 Reverse Transmitter - High Gain FP 
Amps 
0.09 
0.07 
 
6940/44 Reverse Transmitter - High Gain DFB 
Amps 
0.09 
0.09 
 
6940/44 Reverse Switch 
Amps 
0.02 
 
 
 
 
 
 
 
Power Supply DC Current Rating 
Amps 
4.5 
0.5 
1.5 
Power Supply Operating Efficiency 
85  
 
AC Input Low Voltage Cutoff 
V AC 
33 
 
Minimum Restart Voltage 
V AC 
 41 
 
 
  Station Powering Data 
 
 
AC Voltage 
 
6942 Station 
DC 
(Amps at 24 
V DC) 
 
90 
85 
80 
75 
70 
65 
60 
55 
50 
45 
41 
AC Current (A) 
1.2 1.2 1.2 1.2 1.2 1.3 1.5 1.5 1.7 1.8  2.1 
1x2 Configuration 
(1 Std Receiver  
& 2 DFB or FP 
Transmitter) 
 
2.68 
Power (W) 
78 78 78 77 77 77 77 77 78 78  79 
Data is based on stations configured for 2-way operation with status monitoring transponder.  AC currents specified are based on 
measurements made with typical CATV type ferro-resonant AC power supply (quasi-square wave), and standard version DC power 
supply (pn 590902). 
 
 
 
Environmental 
Units 
 
Operating Temperature Range 
degrees 
-40°F to 140°F (-40°C to 60°C) 
Relative Humidity Range 
percent 
5 to 95 
Mechanical  
 
 
Housing Dimensions 
Weight 
Station with 2 RX, 2 TX, 2 power supplies:   39 lbs (17.7 kg) 
20.2 in. L x 10.8 in. H x 10.8 in. D  