Cisco Model 6940 Four Port Optoelectronic Node 870 MHz Datenbogen

Seite von 8
Model 6940 Optoelectronic Node - 5-42/54-870 MHz 
 
6
 
 
Specifications 
 
Electrical 
Units 
 
Notes 
Max. AC Through Current (continuous) 
Amps 
15 
 
Max. AC Through Current (surge) 
Amps 
25 
 
Component DC Power Consumption (typical) 
 
@ +24 V DC 
@ +15 V DC 
@ -6 V DC 
Launch Amplifier with 5 PHD hybrids 
Amps 
2.4 
 
Optical Interface Board 
Amps 
0.22 
 
6940/44 Status Monitoring Transponder Amps 
0.15 
 
6940/44 Standard Optical Receiver Amps 
0.25 
0.01 
0.035 
 
6940/44 High Gain Optical Receiver Amps 
0.35 
0.01 
0.035 
 
6940/44 Optical Transmitter-Standard Gain FP 
Amps 
0.14 
0.07 
 
6940/44 Optical Transmitter-Standard Gain DFB 
Amps 
0.14 
0.09 
 
6940/44 Reverse Switch 
Amps 
0.02 
 
 
 
 
 
 
 
Power Supply DC Current Rating 
Amps 
4.5 
0.5 
1.5 
Power Supply Operating Efficiency 
85 
 
AC Input Low Voltage Cutoff 
V AC 
33 
 
Minimum Restart Voltage 
V AC 
 41 
 
 
 
Station Powering Data 
AC Voltage 
 
6940 Station 
DC 
(Amps at 
24 V DC) 
 
90 
85 
80 
75 
70 
65 
60 
55 
50 
45 
41 
AC Current (A) 
1.3 1.4 1.4 1.4 1.4 1.5 1.7 1.8 1.9 2.1  2.4 
1 Std Receiver 
& 1 DFB or FP 
Transmitter 
 
3.16 
Power (W) 
91 91 90 90 90 90 90 90 91 91  92 
AC Current (A) 
1.4 1.5 1.5 1.5 1.6 1.7 1.9 2.0 2.2 2.4  2.7 
2 Std Receivers  
& 2 DFB or FP 
Transmitters 
 
3.55 
Power (W) 
103 103 102 102 102 102 102 102 103 103  104 
Data is based on stations configured for 2-way operation with status monitor transponder.  AC currents specified are based on measurements 
made with typical CATV type ferro-resonant AC power supply (quasi-square wave), and standard version DC power supply (pn 590902). 
 
 
 
 
 
 
 
Environmental 
Units 
 
Operating Temperature Range 
degrees 
-40
°F to 140°F (-40°C to 60°C) 
Relative Humidity Range 
percent 
5% to 95% 
 
 
Mechanical  
Housing Dimensions
 
Weight 
20.2 in. L x 10.8 in. H x 10.8 in. D 
(51.3 cm L x  27.4 cm H x 27.4 cm D) 
Station with 1 RX, 1 TX, 2 power supplies:   37 lbs (16.8 kg) 
 
Note: 
1.  The total DC power consumption of installed components should not exceed the power supply DC current rating.