Cisco Model 6940 Four Port Optoelectronic Node 870 MHz Datenbogen
Model 6940 Optoelectronic Node - 5-42/54-870 MHz
6
Specifications
Electrical
Units
Notes
Max. AC Through Current (continuous)
Amps
15
Max. AC Through Current (surge)
Amps
25
Component DC Power Consumption (typical)
@ +24 V DC
@ +15 V DC
@ -6 V DC
1
Launch Amplifier with 5 PHD hybrids
Amps
2.4
-
-
Optical Interface Board
Amps
0.22
-
-
6940/44 Status Monitoring Transponder Amps
0.15
-
-
6940/44 Standard Optical Receiver Amps
0.25
0.01
0.035
6940/44 High Gain Optical Receiver Amps
0.35
0.01
0.035
6940/44 Optical Transmitter-Standard Gain FP
Amps
0.14
-
0.07
6940/44 Optical Transmitter-Standard Gain DFB
Amps
0.14
-
0.09
6940/44 Reverse Switch
Amps
0.02
-
-
Power Supply DC Current Rating
Amps
4.5
0.5
1.5
1
Power Supply Operating Efficiency
%
85
AC Input Low Voltage Cutoff
V AC
33
Minimum Restart Voltage
V AC
41
Station Powering Data
AC Voltage
6940 Station
I
DC
(Amps at
24 V DC)
90
85
80
75
70
65
60
55
50
45
41
AC Current (A)
1.3 1.4 1.4 1.4 1.4 1.5 1.7 1.8 1.9 2.1 2.4
1 Std Receiver
& 1 DFB or FP
& 1 DFB or FP
Transmitter
3.16
Power (W)
91 91 90 90 90 90 90 90 91 91 92
AC Current (A)
1.4 1.5 1.5 1.5 1.6 1.7 1.9 2.0 2.2 2.4 2.7
2 Std Receivers
& 2 DFB or FP
Transmitters
3.55
Power (W)
103 103 102 102 102 102 102 102 103 103 104
Data is based on stations configured for 2-way operation with status monitor transponder. AC currents specified are based on measurements
made with typical CATV type ferro-resonant AC power supply (quasi-square wave), and standard version DC power supply (pn 590902).
made with typical CATV type ferro-resonant AC power supply (quasi-square wave), and standard version DC power supply (pn 590902).
Environmental
Units
Operating Temperature Range
degrees
-40
°F to 140°F (-40°C to 60°C)
Relative Humidity Range
percent
5% to 95%
Mechanical
Housing Dimensions
Housing Dimensions
Weight
20.2 in. L x 10.8 in. H x 10.8 in. D
(51.3 cm L x 27.4 cm H x 27.4 cm D)
(51.3 cm L x 27.4 cm H x 27.4 cm D)
Station with 1 RX, 1 TX, 2 power supplies: 37 lbs (16.8 kg)
Note:
1. The total DC power consumption of installed components should not exceed the power supply DC current rating.
1. The total DC power consumption of installed components should not exceed the power supply DC current rating.