Cisco Headend System Release 2.5
738185 Rev B
Disabling OSM Automux
4-3
Verify Your Configuration,
Continued
Verifying Program Numbers
Complete these steps to verify that all BFS QAMs use the same program number for
the OSM session.
1.
On the DNCS Administrative Console, click the DNCS tab and then the
Element Provisioning tab.
2.
Click BIG. The BIG List window opens.
3.
Select the headend corresponding to your primary BFS QAM. Then, on the
File menu, click Open. The Set Up BIG window opens.
4.
Click the PAT Configuration button near the bottom of the window. The BIG
PAT window opens.
5.
Check and record the Program Number for the OSM session in the BIG PAT
table.
Program Number for OSM Session: ____________
Program Number for OSM Session: ____________
6.
Close the BIG PAT window, the Set Up BIG window, and the BIG List
window using the Close or Cancel buttons, or the File menu.
7.
On the DNCS Administrative Console, click the DNCS tab and then the
System Provisioning tab.
8.
Click Source. The Source List window opens.
9.
Select the row corresponding to the secondary OSM source. If you followed
this guide to create this source, the source is named OSM2.
10. On the File menu, click Source Definitions. The Source Definition List
window opens.
11. Complete the following steps for each row in the list.
a) Double-click the row to open the Set Up Digital Source Definition
window.
b) Note the Program Number.
Continued on next page