Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installationsanleitung

Seite von 174
 
 
Mounting the Node 
 
Mounting the Node 
The following procedures detail how to install the housing on a strand (aerial) or in a 
pedestal. 
 
To Install the Node on a Strand (Aerial) 
Complete the following steps to install the node on a strand (aerial). The housing 
does not need to be opened for strand installation. 
Important: The minimum strand diameter should be 5/16 inch. 
 
CAUTION: 
Be aware of the size and weight of the node while strand mounting. 
Ensure that the strand can safely support the weight of the node. 
1  Loosen the strand clamp bolts. 
2  Lift the housing into proper position on the strand. 
3  Slip the strand clamps over the strand and finger-tighten the clamp bolts. This 
allows additional movement of the housing as needed. 
4  Move the housing as needed to install the coaxial cable and connectors. See the 
following diagrams for examples. 
 
 
Note: 
 
Power In may be switched or combined with the Coax Out to maintain street 
access. 
 
If supplying power to the node through the main input port, a power inserter 
must be installed to terminate the RF signal. 
5  Tighten the strand clamp bolts (using a ½-inch torque wrench) from 5 ft-lb to 8 
ft-lb (6.8 Nm to 10.8 Nm). Make sure there is good mechanical contact between 
the strand and the housing. 
Note: A slight tilt of the face of the housing is normal. Cable tension will cause 
the housing to hang more closely to vertical. 
 
OL-29644-03 
27