Cisco Headend System Release 2.5 Installationsanleitung
I-32
SR 2.5/3.5 Direct ASI Installation and Configuration Procedures
78-738190-01 Rev B
Restart the BFS and OSM Processes,
Continued
8.
When the current state of the BFS Server group is Running, type the
number associated with DNCS HCT Manager & OSM and then press
Enter.
Result: The Dncs Control window updates to display a message
Result: The Dncs Control window updates to display a message
prompting you to enter the target status for the entire element group or to
type E to display the individual elements of the group.
9.
Type e and then press Enter.
Note: The Dncs Control window updates to display the individual
Note: The Dncs Control window updates to display the individual
elements of the DNCS HCT Manager & OSM group.
10. Type the number associated with /dvs/dncs/bin/OSM and then press
Enter.
Result: The Dncs Control window updates to display a message
Result: The Dncs Control window updates to display a message
prompting you to enter the target status of the selected element.
11. Type 2 (for running) and then press Enter.
Result: A confirmation message appears.
12. Type y (for yes) and then press Enter.
Result: After a few moments, the Dncs Control window updates to
display the current state (Curr Stt) of the selected element.
13. Wait until the current state of the /dvs/dncs/bin/OSM process is
Running.
Note: The Dncs Control window updates automatically every few
Note: The Dncs Control window updates automatically every few
seconds or you can press Enter to force an update.
14. When the current state of the /dvs/dncs/bin/OSM process is Running,
follow the on-screen instructions to exit from the dncsControl utility.
Powering Down the BFS BIG
Conclude your procedure for configuring your system for Direct ASI by turning off
power to the BFS BIG.