Cisco Cisco Workload Automation 6.3 Betriebsanweisung
45
Configuring service.props
service.props Properties
LoginConfig
BusinessObje
cts BI
Platform,
BusinessObje
cts Data
Services
cts BI
Platform,
BusinessObje
cts Data
Services
<none>
Specifies the location of the login configuration if using
WinAD or LDAP authentication. For example:
WinAD or LDAP authentication. For example:
LoginConfig=c:\\windows\\bscLogin.conf
where
“c:\\windows\\bscLogin.conf” is the
location of the login configuration information. Note the
use of \\ if this is a Windows location.
use of \\ if this is a Windows location.
MaxLogFiles
Informatica,
JDBC,
PeopleSoft
JDBC,
PeopleSoft
50
(Optional) – Number of logs to retain.
OUTPUT_ASYNC_LOGOUT
Informatica
N
Setting this flag to Y avoids jobs getting stuck in
Gathering Output status.
Gathering Output status.
OUTPUT_SYNC
All
Y
Enables concurrent output gathering on a connection. To
enable this feature, set the value to N.
enable this feature, set the value to N.
POLL_SYNC
All
Y
Enables concurrent polling on connections of the same
type. This is helpful when there is a heavily load on one
connection of an adapter. The heavily loaded connection
will not affect the other adapter connection. To enable
this feature, set the value to N.
type. This is helpful when there is a heavily load on one
connection of an adapter. The heavily loaded connection
will not affect the other adapter connection. To enable
this feature, set the value to N.
QUERY_TIMEOUT
Oracle Apps
N
Y or N. If set to Y, the timeout value defined using the
parameter QUERY_TIMEOUT_VALUE is applied to the
SQL queries. Default value is N or empty.
parameter QUERY_TIMEOUT_VALUE is applied to the
SQL queries. Default value is N or empty.
QUERY_TIMEOUT_VALUE
Oracle Apps
unset
The time period in seconds that SQL queries wait before
timeout. If 0 or not set, there is no timeout.
timeout. If 0 or not set, there is no timeout.
READPCHAINLOG
SAP
Y
Used to control the log gathering in SAP Process Chain
jobs. This property depends on the Summary Only check
box of the job definition Options tab.
jobs. This property depends on the Summary Only check
box of the job definition Options tab.
SCANFOR_SESSIONSTATS
Informatica
Y
Y or N - Set this parameter to N to turn off the default
behavior of Informatica jobs collecting the session
statistics during the job run.
behavior of Informatica jobs collecting the session
statistics during the job run.
SCANFOR_SESSIONSTATS_A
FTER_WF_ENDS
FTER_WF_ENDS
Informatica
N
Y or N - Set this parameter to Y to turn off the gathering
of session statistics during each poll for the status of
Informatica jobs.
of session statistics during each poll for the status of
Informatica jobs.
TDLINFA_LOCALE
Informatica
<none>
Points to the Load Manager Library locale directory. See
“Configuring the Informatica Adapter” in the Informatica
Adapter Guide for how to set this for Windows and Unix
environments.
“Configuring the Informatica Adapter” in the Informatica
Adapter Guide for how to set this for Windows and Unix
environments.
TDLINFA_REQUESTTIMEOUT
Informatica
<none>
(Optional) – The number of seconds before an API
request times out. The default is 120 seconds, if not
specified.
request times out. The default is 120 seconds, if not
specified.
TDLJDBC_LIBPATH
JDBC
<none>
(Windows only, optional) An alternate path to the JDBC
library files. The library file path should have been
configured given system environment variables. This
option is available in case you wish to use an alternate
set of libraries and may be helpful for trouble-shooting
purposes.
library files. The library file path should have been
configured given system environment variables. This
option is available in case you wish to use an alternate
set of libraries and may be helpful for trouble-shooting
purposes.
Property
Applicable
Adapter(s)
Adapter(s)
Default
What It Controls