Cisco Model 6109 6 MHz Off-Air Reference (NTSC) Installationsanleitung
Chapter 5 Advanced Operations
346
4039132 Rev B
Sharing a QAM Chassis Between Two USRMs
Cisco GQAM chassis are capable of being shared between two USRM servers.
Sharing GQAMs
No special configuration on the USRM is required to share GQAMs. However, the
GQAM code version must be version 4.2 or later.
GQAM code version must be version 4.2 or later.
Sharing RFGW-1 and xDQA24 QAMs
The following code versions are required to share these QAMs between two USRMs:
RFGW-1 code must be version 1.3.9 or later
xDQA code must be version 4.1.39
On the USRM, any QAM output port that is controlled by another USRM must have
its AddminState set to OutOfService. This can be done from the web interface or via
a configuration file, as follows.
1 From the USRM web interface:
its AddminState set to OutOfService. This can be done from the web interface or via
a configuration file, as follows.
1 From the USRM web interface:
a Select the Resource Manager - QAMs - QAM <QamName> - Output Ports
page, where QamName is the QAM involved.
b Set the AdminState of the ports controlled by another USRM to OutOfService
and click Commit Changes.
OR
2 Via a Configuration file:
a In the QAM configuration file, set the PortTable.AdminState entries of the
ports controlled by another USRM to OutOfService.
b Load and run the configuration file using Platform - ConfigManager in the
web interface.