Cisco Cisco Nexus 2224TP GE Fabric Extender Weißbuch

Seite von 70
 
 
© 2014 Cisco | IBM. All rights reserved. 
Page 9 
The relationship of host-side ports to parent switch fabric ports is static. If a fabric interface fails, all its associated 
host interfaces are brought down and will remain down until the fabric interface is restored. Figure 3 shows static 
port mappings.  
Figure 3:    Static Port Mapping Based on Max Link Parameter 
 
Port Channel Fabric Interface Connection 
The Port Channel fabric interface provides an alternative way of connecting the parent switch and the Cisco 
Nexus B22 for IBM fabric extender. In this mode of operation, the physical fabric links are bundled into a single 
logical channel. This approach prevents a single fabric interconnect link loss from disrupting traffic to any one 
server. The total bandwidth of the logical channel is shared by all the servers, and traffic is spread across the 
members through the use of a hash algorithm. 
 
For a Layer 2 frame, the switch uses the source and destination MAC addresses. 
 
For a Layer 3 frame, the switch uses the source and destination MAC addresses and the source and 
destination IP addresses. 
Since both redundancy and increased bandwidth are possible, configuration of the fabric links on a Port Channel 
is the most popular connection option.