Cisco Cisco 1 GHz GainStar Amplifier Installationsanleitung
Chapter 2 Installation and Configuration
Before You Begin
The procedures in this chapter assume that you have completed the following:
Prepared the installation site
Located the coaxial cable, with or without the pin-type coaxial connectors
mounted on the cable
Required Tools
Before you start, make sure that you have the following tools:
Torque wrench with a 1/2-inch socket
Cross screwdriver
Heavy-duty wire cutters or snips
Torque wrench set
Torque Specifications
The following table lists the torque specifications for the GainStar Line Extender.
Fastener
Torque Specification
Illustration
Housing closure bolts
6.8 Nm to 9.0 Nm
Housing grounding screw
0.9 Nm to 1.0 Nm
Housing plugs test point port
plugs
6.8 Nm to 9.0 Nm
RF PG11 to 5/8” adapter
12.0 Nm to 16.0 Nm
Strand clamp mounting
bracket bolts
6.8 Nm to 9.0 Nm
10