Chapter 4    Troubleshooting 
 
 
 
Low or Degraded Forward RF Signal 
The forward RF signal can be measured at the GainStar Line Extender module 
forward input and    forward output main test point. 
Low or Degraded Forward RF Signal Troubleshooting Table 
Before you begin troubleshooting for a low or degraded forward RF signal, verify 
that the GainStar Line Extender is receiving the proper forward RF input signal from 
the upstream amplifier. 
Important: You cannot balance the GainStar Line Extender without the proper forward 
RF input signal. 
Make sure you have configured the GainStar Line Extender module according to the 
specifications in the design print, and the GainStar Line Extender has warmed up for 
approximately one hour. 
Make sure you are using the proper tilt reference when setting levels. An 862 MHz 
or 1 GHz design balanced at 550 MHz requires a corrected tilt reference to 
compensate for the difference in carrier levels between 550 MHz and 862 MHz or 1 
GHz. The tilt reference at 550 MHz is lower than the tilt reference at 862 MHz or 1 
GHz. Refer to the tilt charts in Technical Information for more information. 
Possible Cause 
Solution 
The forward RF signal is weak or degraded 
at the forward input test point. 
 
Verify that the line extender is receiving the 
proper forward RF input signal from the 
upstream amplifier.   
Important: You cannot balance the line 
extender without the proper forward RF 
input signal. 
The forward RF signal is normal at the 
forward input test point, but it is weak or 
degraded at the forward output test point. 
Verify that all the proper accessories, pads, 
EQs, and signal directors (if applicable) are 
firmly installed in the correct locations. 
Verify that the factory installed accessories 
are firmly installed in the correct locations. 
Replace the RF mainboard. 
 