Cisco Cisco 1 GHz GainStar Amplifier Installationsanleitung
Appendix A
Technical Information
105 MHz Inverse Equalizer Loss Table
EQ
Value
(dB)
(dB)
Part
Number
Typical Insertion Loss(dB)at Various Frequencies(MHz)
105
550
600
650
750
862
1000
0
GS-FIEQ-
105-00-04
0.01
0.21
0.24
0.25
0.30
0.34
0.42
1
0.39
0.96
1.02
1.05
1.14
1.24
1.44
2
0.53
1.65
1.73
1.79
1.93
2.12
2.45
3
0.56
2.37
2.47
2.53
2.73
2.98
3.40
4
0.55
3.06
3.19 3.28
3.52
3.81
4.29
5
GS-FIEQ-
105-05-09
0.31
3.56
3.74
3.92
4.29
4.80
5.65
6
0.29
3.96
4.17
4.39
4.84
5.44
6.43
7
0.26
4.79
5.07
5.36
5.93
6.67
7.78
8
0.24
5.03
5.38
5.72
6.41
7.26
8.57
9
0.22
5.49
5.91
6.31
7.13
8.12
9.58
10
GS-FIEQ-
105-10-14
0.56
7.28
7.69
8.08
8.87
9.88
11.50
11
0.54
7.83
8.30
8.75
9.63
10.68 12.30
12
0.51
8.46
9.01
9.58
10.61 11.83
13.53
13
0.49
8.85
9.49
10.11
11.29
12.61
14.41
14
0.47
9.11
9.83
10.55
11.96
13.58
15.81
58
OL-31945-02