Cisco Laser Link Receivers Datenbogen
Laser Link Mainframes
2
Specifications
Mainframe
Electrical
Units
AC and DC Versions
Output Voltage
(Nominal)
V
DC
24
Ripple and Noise
(Max.)
(Output Volt = 24 V)
1% peak-to-peak
Output Current
(Max.)
1
amps 15.6
Output Power
(Max.)
W
375
Specified Temperature Range
°F (°C)
-4 to 149 (-20 to 65)
AC Version
DC Version
Input Voltage Range
2
V
85-264
2
40 ~ 60
Input Current
3
amps n/a
12
Fuse Type
8 amp AC input line fuse
15 amp thermal
magnetic breaker
Safety Approvals
Units
Specification
Safety Agency Approvals
CSA 22.2 No. 234, U.L.® 1950, EN 60950, CE
Physical
Operating Temperature
°F (°C)
4 to 149 (-20 to 65)
Relative Humidity
(Non condensing)
%
5-95%
Mounting
in. (cm)
Standard 19 (48.26) rack/optional 23 (58.42)
Dimensions (H x W x D)
in. (cm)
8.75 x 19 x 21.1 (22.23 x 48.26 x 53.59)
Weight
lbs. (kg)
32 (14.5)
Notes:
1. Derated for temperature, 65 °C
2. AC input range selection is fully automatic
3. Typical @ 48 V dc and maximum output current
1. Derated for temperature, 65 °C
2. AC input range selection is fully automatic
3. Typical @ 48 V dc and maximum output current
Mini-Mainframe
Power
Units
Specification
Input Current
amps
2.5 @ -48 V DC
2 @ 120 V AC
Output Power
(Max.)
W
100
Output Voltage
V DC
24 ±2.5%
Front Alarm
“A” Supply, “B” Supply
V
>26.4
<21.6
<21.6
Physical
Operating Temperature
°F (°C)
-4 to 149 (-20 to 65)
Relative Humidity
(Non condensing)
20-100%
Mounting
in. (cm)
Standard 19 (48.26) and 23 (58.42) rack
Dimensions (H x W x D)
in. (cm)
3.5 x 19 x 19 (8.89 x 48.26 x 48.26)
Weight
lbs. (kg)
15 (6.80)